20 CHAPTER 2 CONNECTING POWER AND SURGE PROTECTION
GND/-DC (Black)
+DC (Red)
+485 (White)
-485 (Blue)
CTS (Brown)
RTS (Orange)
Power Drain
232 Drain
485 Drain
Ground (Gray)
TD (Yellow)
RD (Purple)
Figure 2.3 – Surge Protected Terminal Connections (Top)
Figure 2.3 above shows the PROTECTED side of the Click 200. e UNPROTECTED
side of the Click 200 contains the same screw terminal connections, but are reversed from
left to right.
Note
See Appendix B for a description of how to wire the Click 200 using the old SmartSen-
sor cable as well as for a cable connector pin out diagram.
Wiring to Earth Ground
ALL Click 200 devices should be mounted on a DIN rail that is connected to earth ground
either through an earth-grounded chassis or a 16 AWG or larger grounding wire attached
to a 7-ft. (2.1-m) grounding rod. Follow the steps below to correctly wire to earth ground:
1 Connect the grounding wire from either the DIN rail or a GND screw terminal on
the UNPROTECTED side of the Click 200 to the lug bolt on the inside of the pole-
mount box.
2 Connect another grounding wire from the exterior lug bolt to earth ground (see Figure
2.4).