14 CHAPTER 1 CLICK 340/341/342 MANAGED SWITCHES
e Web server, SNMP agent, RS-232 (V.24) interface and IGMP snooping are active.
e Rapid Spanning Tree WBM conguration page is activated.
e Multicast WBM conguration page is activated.
e alarm contact only opens in the event of non-redundant power supply.
e aging time is set to 48 seconds.
Assigning IP Parameters
When the supply voltage is switched on, the switch sends BootP requests to assign IP pa-
rameters. BootP is used to obtain IP addresses and boot remote computers over a network.
Note
The BootP function can be deactivated via Web-based management. By default upon
delivery, the BootP function is activated.
e assignment of valid IP parameters is vital to the management function of the switch.
Options for assigning IP parameters include:
Conguration via the BootP (default upon delivery)
Static conguration via the management interfaces
Note
The assignment of IP parameters with IP Assign is described in Chapter 3.
IP parameters comprise the following three elements: IP address, subnet mask, and default
gateway/router.
Valid IP addresses are:
000.000.000.001 to 126.255.255.255
128.000.000.000 to 223.255.255.255
Valid multicast addresses are:
224.000.000.001 to 239.255.255.255
Valid subnet masks are:
255.000.000.000 to 255.255.255.252
e IP address of the gateway/router must be in the same subnetwork as the address of the