38 CHAPTER 4 WEB-BASED MANAGEMENT (WBM)
transmitted via the selected ports. To do this, a measuring instrument (PC) is connected to
the destination port, which records the data, yet must not itself be activated.
Figure 4.19 – Port Mirroring Web Page
Note
If ports are set with the same value, port mirroring will be disabled. The source port
is set to “0.
e port capacity is calculated according to the set transmission parameters.
Example
A source port is operated at 100 MBps and reaches a capacity of 5%. The destination
port is operated at 10 MBps. Therefore, with the same volume of data the destination
port reaches a capacity of 50%.
Display Menu
e Display menu contains status information about the switch (see Figure 4.20).
Figure 4.20 – Menu Display
Alarm Contact Menu
e Alarm Contact menu allows you to set whether and for which events the alarm contact