Wavetronix SmartSensor Advance Extended Range (SS-200E) - Use Uživatelský manuál Strana 124

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 148
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 123
CHAPTER 11  TOOLS 123
e following window will pop up asking you to conrm that you want to restore the sensor
to factory defaults:
Figure 11.7 – Restore to Factory Defaults
e process should take only a few seconds. If it is successful you will see a success message.
Otherwise, you will see a failure message.
Figure 11.8 – Restore Defaults Results
Beam Alignment Tool
Click the Beam Alignment icon to start the Beam Alignment tool (see Figure 11.9). is
tool is used to help the person installing the sensor to visualize the invisible radar beam
footprint, based on the sensor mounting oset and mounting height.
By default, the values in the recommended alignment table (see Appendix D and Table D.1)
are now entered automatically when the Alignment Tool screen rst appears. e align-
ment tool values will be correct only if you have correctly put height and oset information
in the 1. Installation Details screen.
Figure 11.9 – Beam Alignment Tool
Zobrazit stránku 123
1 2 ... 119 120 121 122 123 124 125 126 127 128 129 ... 147 148

Komentáře k této Příručce

Žádné komentáře